Replacing a tap is roughly an hour’s work and something you can easily do yourself. The order is always the same: close the isolation valves, open the tap to release the pressure, undo the flexi hoses, loosen the fixing nut under the worktop, old tap out, new tap in the other way round. Two things have to be right before you start: the hole in your worktop or basin (35 millimetres as standard) and the type of tap (high pressure or low pressure). Buy a high pressure tap while there is an open-vented water heater under your sink and that heater will spring a leak within a day, or your cupboard will be swimming.

That last one is the mistake most people make, and not a single DIY store leaflet warns you about it clearly.

Everything you need is below: how to check in thirty seconds which type of tap you need, which connection sizes you will run into, the complete step-by-step for kitchen and bathroom, when to use PTFE tape and when definitely not, what it costs, how much water and gas you save with the right aerator, and the point at which you are better off calling someone.

Are you allowed to replace a tap yourself?

Yes. You are allowed to work on the drinking water installation in your own home. There is no obligation to bring in a registered installer the way there is with gas.

Your installation does have to meet the applicable standard for drinking water systems. This article is based on the Dutch NEN 1006 and the accompanying Waterwerkbladen, which set out the requirements for backflow prevention (non-return valves), among other things. Source: Praktijkcodes Drinkwater

For an ordinary tap swap that means three things in practice:

  1. Buy a tap with a recognised approval mark for drinking water contact, for example Kiwa Watermark. That guarantees the materials are suitable for drinking water. Source: Kiwa
  2. Never connect a garden hose or a washing machine straight onto a tap without backflow protection.
  3. Never reuse old sealing washers or old hoses. They cost a few euros new and they are the only genuine weak link.

Renting? A tap usually falls under the minor maintenance that sits with the tenant. But a tap that fails on its own is normally the landlord’s problem. Call first, because then you may not have to pay for it at all.

First check: high pressure or low pressure?

This is the most important question in the whole article. Do this check before you order anything.

Look under your sink or under your basin. Is there a water heater there (a small white or grey cylinder, usually 5, 10 or 15 litres)? Then you need to know whether it is a closed (unvented, high pressure) or an open (vented, low pressure) unit.

Count the hoses on your current tap.

What you see What it means What you need to buy
2 hoses under the tap high pressure system ordinary high pressure tap
3 hoses under the tap open-vented water heater low pressure tap
No heater, 2 hoses high pressure via combi boiler or instantaneous heater ordinary high pressure tap

With an open-vented heater the tap sits before the heater, not after it. The tap shuts off the cold water supply, and the water heating up inside the cylinder expands and is allowed to drip away through the tap spout. That is why this kind of tap has three connections: cold in, cold to the heater, hot back out of the heater. Source: Hansgrohe

Put an ordinary high pressure tap on there and you seal off the expansion of the heated water. The heater has nowhere to send the pressure. Expect a leaking cylinder, a burst connection, or at best a cupboard full of water.

It does not work the other way round either: a low pressure tap on a normal mains supply will drip and make noise.

Watch out: an under-sink heater can be either sealed or vented. It is not a question of brand or shape. Count the hoses, or read the data plate on the heater. Does it say “vented”, “open”, “low pressure” or “non-pressurised”? Then you need a low pressure tap.

The sizes that have to be right

Hole size: nearly always 35 millimetres

The European standard for a single-hole tap is 35 millimetres. That means almost every kitchen and basin tap fits almost every worktop. That is the nice thing about this job: you are rarely tied to one brand.

Exceptions you should still check:

  • Older basins with two or three holes (separate hot and cold taps). A single-lever mixer will not fit there without a cover plate.
  • Some designer taps need 40 millimetres.
  • Boiling water taps and taps with a pull-out spray sometimes have a thicker shank.

Just measure the hole with a vernier caliper or a ruler before you order.

Worktop thickness: the forgotten measurement

The fixing bolt under your tap has a limited length. With a thin stainless steel sink (0.8 to 1 millimetre) you often need an extra spacer washer, while with a thick granite composite or natural stone worktop (30 to 40 millimetres) the bolt can be just a bit too short.

Check the product specification for the maximum worktop thickness. Does it say 40 millimetres, and do you have a 30 millimetre worktop with an undermount sink adding 10 millimetres of rim? Then you are right on the limit.

Connection sizes: 3/8″, 1/2″ and 12 millimetre compression

These are the three you will run into in most homes:

Connection Where you find it Note
3/8″ female thread the union nut on the flexi hose of your new tap by far the most common
12 mm compression older isolation valves and direct pipe connections compression fitting 12 x 12 or reducer 15 x 12
1/2″ male thread cloakroom taps, wall-mounted taps, washing machine valves bigger, coarser

Modern taps come with flexi hoses that end in a 3/8″ union nut or a 12 millimetre compression connection. Is there a 15 millimetre copper pipe on your wall? Then you fit a 15 x 12 millimetre reducing compression fitting on it, or simply an isolation valve. Source: Plieger

Important: never screw a flexi hose onto a plain compression fitting or onto the thread of a union nut. That will not seal reliably. The hose belongs on a connection with a flat seat and a rubber washer. Source: Plieger

Hose length

Standard hoses are 30 to 50 centimetres. Is your isolation valve low down in the cupboard, or do you have to route around a waste pipe? Then buy longer hoses straight away (60 to 100 centimetres). A hose that is too short and pulled tight is a leak waiting to happen.

Tools: what you really need

Here we go:

  1. Water pump pliers (two pairs is nice: one to hold, one to turn)
  2. Open-ended or ring spanners in 10, 12, 17 and 19 millimetres
  3. Basin wrench, a long thin socket tool for that one unreachable nut at the back. This is the tool that makes the difference between twenty minutes and two hours.
  4. PTFE tape
  5. Bucket, old towel and a torch or head torch
  6. Screwdrivers (cross-head and flat)
  7. Possibly an Allen key set for the new tap

What you do not need: hemp and jointing compound. That is professional kit for galvanised thread. For an ordinary tap swap, PTFE tape is more than enough.

A tip nobody gives you: put an old towel or a piece of bubble wrap on the floor of your base unit. Some water always comes out, and chipboard that gets wet swells up and never goes back.

Step-by-step: replacing a kitchen tap

Step 1: find your stopcock

Before you even begin. Know where it is (meter cupboard, crawl space or under the stairs) and whether it still turns. I once undid a tap and only then discovered that the isolation valve no longer closed. That is a wet lesson.

Step 2: close the isolation valves

Both of them, hot and cold. Clockwise is closed. Seized up with limescale? Do not force it with pliers, because you will shear the spindle. Instead, open it a fraction first and then close it, working it back and forth a few times.

If it really will not budge, shut off the stopcock and replace the isolation valve while you are at it (see further down).

Step 3: release the pressure

Open the tap, both positions, and let it drain. Then set the tap to the middle position and leave it open. There is always some water left in the pipe. Bucket underneath.

Step 4: disconnect the flexi hoses

Under the sink, the union nuts of the flexi hoses sit on the isolation valves. Hold the isolation valve steady with pliers and undo the union nut with a spanner. If you only turn the nut, you turn the isolation valve with it and you will break it out of the wall.

Is there still a thin hose going to a pull-out spray or a dishwasher valve? Disconnect that too.

Step 5: undo the fixing under the worktop

Under the tap you will usually find:

  • a threaded rod with a bridge plate (two studs and a bracket), or
  • one large central nut on a threaded sleeve.

This is where the basin wrench earns its keep. The space is tight, you are looking up at the underside of a sink and the nut is often furred up with limescale. What helps: a squirt of penetrating oil, ten minutes’ wait, and only then force.

Step 6: lift out the old tap

Pull it out from above, hoses and all. Is it stuck to the worktop with old sealant or limescale? Cut around the edge with a utility knife and lever it free with a plastic scraper, not a screwdriver against your stainless steel.

Step 7: clean the hole

This is the step everyone skips and the one that decides whether you end up with a neat result or a tap that sits crooked after a month. Scrape away all the old sealant, limescale and rust marks. Dry the worktop.

Is there corrosion in the hole of a stainless steel sink? Treat it now, because that is where the brown rim starts that you will never get rid of later.

Step 8: fit the new tap

Feed the hoses through the hole and set the tap in place. Watch the base seal: there should be a rubber or plastic washer between the tap and the worktop. Leave it out and splashes from your worktop will run straight into the cupboard below.

Turn the tap to the right orientation (spout over the sink, lever within reach) and tighten it from below. Hand tight plus half a turn. No more. Too tight means a bowed sink base or a cracked ceramic worktop.

Extra sealant is usually unnecessary and often works against you, because you can no longer adjust the tap afterwards. Only do it if the manufacturer specifies it.

Step 9: connect the hoses

Hot on the left, cold on the right (that is how it is marked on your tap too, red and blue). Screw the union nuts onto the isolation valves by hand and then give them about half a turn with the spanner. Hold the isolation valve steady again.

No PTFE tape goes on this joint. There is already a rubber washer inside the union nut doing the sealing. Adding PTFE tape does not make it tighter, only crooked. Source: Plieger

Step 10: flush and leak test

Take the aerator (the small mesh insert) out of the spout, and only then turn the water on. There is always some dirt and metal swarf in new pipes and hoses. Otherwise that debris lodges in your new aerator or in the ceramic cartridge.

Open the isolation valves slowly. Run the tap for a minute, cold and hot.

Then dry every joint with a piece of kitchen roll and hold that paper against it for twenty seconds. Wet paper means a leak, even if you can see nothing with the naked eye.

Check again after an hour, and once more the next morning. A drip an hour only shows up after a day, and by then your cupboard base has already swollen.

Basin taps: what is different

The principle is identical, but there are four differences that can cost you hours.

1. The space is even tighter. Behind a basin there is often barely 10 centimetres. Here a basin wrench is not a luxury but a necessity. Consider taking the basin off first if it is mounted on brackets.

2. The waste. With a tap that has a pop-up rod (the knob behind the tap that raises and lowers the plug) there is a whole linkage attached to it. A new tap usually means a new waste as well. Buy it at the same time, because an old pop-up rod almost never fits a new tap.

Want to avoid the hassle? Choose a tap without a pop-up rod and fit a click-clack waste (push-button plug). Simpler, fewer parts, less chance of a leak.

3. Cloakroom taps are different. A small tap in the downstairs loo is often a cold-only tap with a 1/2″ male thread that goes straight onto the pipe or onto a wall plate. There you do use PTFE tape (see below).

4. The trap is in the way. Take it off, empty it over a bucket and clean it while you are there. You are down there anyway.

PTFE tape: when yes and when no

This is where things often go wrong, so let us be clear.

Joint PTFE tape?
Flexi hose onto isolation valve (rubber washer in the union nut) No
Tap onto flexi hose (factory fitted) No
Compression fitting (brass olive) No
Isolation valve onto wall pipe (tapered thread) Yes
Cloakroom tap 1/2″ onto wall plate Yes
Hose connector / washing machine valve Yes

The rule is simple: if rubber does the sealing, no tape. Metal on metal via a thread, tape.

Here is how to do it properly: wrap 10 to 12 turns of tape tightly around the thread, in the direction of tightening (clockwise as you look at the end), so the tape does not turn with the fitting and unravel as you tighten. Then tighten hand tight plus about a quarter turn with the pliers. Source: LeidingDeal

Brass is soft. Anyone who leans on it with half a metre of pliers flattens the thread and ends up with a leak that can never be sealed again.

Replace the isolation valve while you are at it

This is where the biggest time saving of the whole job sits, and almost nobody does it.

Isolation valves are often as old as the kitchen. They fur up, the rubbers harden and after twenty years they no longer close fully. The result: in five years you want to do something to that tap and you still have to shut off the stopcock and drain half the house.

Two new isolation valves cost a few euros and the pipe is already empty anyway.

Here is how:

  1. Shut off the stopcock and drain a low outlet (outside tap, or otherwise the lowest tap in the house).
  2. Undo the old isolation valve. Hold the wall pipe steady if you can.
  3. Clean the thread in the wall plate. Get all the old tape and hemp out.
  4. Apply new tape, 10 to 12 turns, in the direction of tightening.
  5. Screw the new valve in, with the outlet facing forward and sitting straight.
  6. Open the stopcock slowly and check.

Going from an old 12 millimetre compression model to a modern 3/8″ version? No problem, that is a standard item. Just measure whether the thread in the wall is 1/2″ or 3/8″.

No isolation valve there at all? Then fit one. That is the best ten minutes you can invest in your water system.

The eight mistakes that cause leaks

Here is the list. Have a look at what you recognise. Here we go:

  1. A high pressure tap on an open-vented heater. Number one, and the most expensive. Count your hoses.
  2. PTFE tape on a rubber seal. Makes it leak instead of seal.
  3. Overtightening. Brass and plastic give way and crack. Hand tight plus half a turn is enough. Source: GAMMA
  4. Not holding the isolation valve steady. You twist the wall pipe, and then you are leaking behind your tiles.
  5. Forgetting the base seal. Splashes then run past the tap base into your cupboard. You only notice when the base swells.
  6. Pulling the hose tight or bending it too sharply. A flexi hose is allowed a generous curve, not a kink. Buy longer.
  7. Leaving the aerator in while flushing. Dirt from the pipe blocks it instantly, and sometimes the cartridge as well.
  8. Not retesting after a day. One drip an hour is 24 drips a day and a soaked cupboard base within a week.

What does it cost?

An indication, in sensible ranges.

Item Range
Basic kitchen mixer tap 40 to 120 euros
Kitchen tap with pull-out spray 100 to 300 euros
Low pressure kitchen tap 60 to 200 euros
Basin mixer tap 40 to 200 euros
Boiling water tap (tap plus tank) 800 to 2,000 euros
Two isolation valves 15 to 40 euros
Flexi hoses (pair) 10 to 25 euros
Click-clack waste 15 to 40 euros
Basin wrench 10 to 25 euros
Plumber for the fitting only 100 to 200 euros

So doing it yourself saves you roughly 100 to 200 euros in labour, plus the call-out charge. With a boiling water tap I would have the tank connection checked, because that involves an earthed socket under the sink.

While you are there: save water and gas

You have the tap in your hands anyway. This is the moment.

A standard kitchen tap delivers roughly 9 to 15 litres per minute. With a good aerator or flow restrictor you bring that down to 5 to 6 litres per minute, without the flow feeling weak, because air is mixed in with the water. Source: Vitens

Kitchen tap flow with and without an aeratorWithout aeratorWithout aerator: 12 litres per minute12 litres per minuteWith good aeratorWith good aerator: 6 litres per minute6 litres per minute
The article's example: a good aerator halves the flow from 12 to 6 litres per minute without the flow feeling weak.

Do the maths. Say you run your kitchen tap for an average of 20 minutes a day. Going from 12 to 6 litres per minute saves 120 litres a day, or roughly 40 cubic metres a year.

Dutch households pay an average of 2.71 euros per cubic metre of drinking water in 2026, including water tax and VAT. Source: Vewin Prices vary by country and supplier, so run the numbers with your own tariff.

That is roughly 100 euros’ worth of water. And the real gain sits in the portion that was hot

What an aerator saves on 20 minutes of tap use a day120 litresless water used per day40 m³roughly saved per year€ 100roughly the value of that water peryear
Going from 12 to 6 litres per minute, based on the Dutch average water price in 2026. Run the numbers with your own tariff.

water: you no longer have to heat it, and that saves gas or electricity. For an aerator costing a few euros, that is a payback time measured in days.

Mind the thread size. Aerators come in M22 male and M24 female (and sometimes M18 or M28 on designer taps). Take the old one to the shop or measure it. The wrong size simply will not fit.

Two things you should not do:

  • No restrictor on a low pressure tap. With an open-vented heater the water has to be able to escape freely. Fitting a restrictor puts pressure into a system that was never built for it.
  • No restrictor on a shower fed by an instantaneous heater that switches on flow rate, because then it will not fire up at all.

Tap maintenance: limescale is the enemy

The water is fairly hard across large parts of the country. Limescale eats away at the cartridge and at the aerator.

  • Every 3 to 6 months: aerator out, overnight in white vinegar, rinse, back in. That solves 80 per cent of all complaints about a “poor flow”.
  • Weekly: wipe the tap dry after use. Sounds excessive, but chrome stays good for years that way.
  • Never: abrasive cleaner or aggressive limescale remover on brushed brass, copper or matt black taps. That coating never comes back.
  • Dripping? On a single-lever mixer that is usually the ceramic cartridge. On branded taps you can buy it separately and swap it in ten minutes. So often no new tap needed at all.

A tip for when you buy a new tap: check whether the cartridge is available as a separate part. With a branded tap it is, with the cheapest own-brand models often not. That decides whether your tap lasts ten years or three.

When do you call a plumber after all?

Fred is the last person to talk you out of a job, but there are four situations where I pick up the phone myself:

  1. Lead pipes. Grey, soft, you can scratch them with a fingernail. Never turn anything on them. Lead water pipes should be replaced anyway.
  2. The wall pipe turns with the fitting or snaps off. Then you have a hole in a tiled wall and a pipe under pressure. That is not a job for a small bucket.
  3. There is no stopcock that still closes. Call your water company, they can shut off the connection out in the street.
  4. A boiling water tap needing a new socket under the worktop. You can do the plumbing yourself, but the electrical part in a wet area is better left alone.

Not sure about your heater type and can’t work it out? Take a photo of the data plate and ask the supplier. That costs five minutes and saves a flooded cupboard.

Frequently asked questions

How do I know whether I need a low pressure or a high pressure tap?

Count the hoses under your current tap. Three hoses means an open-vented water heater and therefore a low pressure tap. Two hoses means a normal high pressure system. Not sure? Read the data plate on the heater under your sink: if it says “vented”, “open” or “low pressure”, you need a low pressure tap.

What hole size does a kitchen tap need?

The European standard is 35 millimetres for a single-hole tap. That means virtually every tap fits virtually every worktop. Some designer taps need 40 millimetres, and older basins sometimes have two or three holes. Measure the hole before you order.

Do I need PTFE tape on the flexi hoses?

No. There is already a rubber sealing washer inside the union nut of a flexi hose. Adding PTFE tape does not help and can actually pull the seal out of line. You only use PTFE tape on metal threaded joints without rubber, such as an isolation valve onto the wall pipe or a cloakroom tap with a 1/2″ thread.

How long does it take to replace a tap?

Allow 45 minutes to an hour and a half if everything goes normally. The time goes into the nut under the worktop that is furred up with limescale. If you are also replacing the isolation valves and the waste, add another hour. Do not start at ten on a Friday evening, because the DIY store will be shut if one of the sizes turns out to be wrong.

My tap leaks after replacing it, what now?

Close the isolation valves first. Then find where it is coming from by drying every joint and holding kitchen roll against it. Leaking at the union nut? Tighten it a fraction further, and if that does not help, undo it and check that the rubber washer is seated properly and straight. Leaking at the tap base on your worktop? Then the base seal is sitting crooked or missing.

Can I replace an isolation valve myself?

Yes, and it is a good moment while you are doing the tap anyway. Shut off the stopcock, drain the lowest outlet, undo the old valve, clean the thread, apply 10 to 12 turns of PTFE tape in the direction of tightening and tighten the new valve hand tight plus about a quarter turn. No harder, because brass is soft.

Why is my water flow weak after replacing the tap?

Usually there is dirt from the pipework in the aerator. Unscrew the mesh insert, rinse it out and put it back. If the flow stays weak, check that both isolation valves are fully open and that neither flexi hose has a kink. In the Netherlands the pressure in most homes sits between 2 and 4 bar, so the supply pressure is rarely the problem. Source: Drinkwaterplatform


In short: count your hoses first to find out whether you have high or low pressure, measure your hole (nearly always 35 millimetres), buy new isolation valves and longer hoses at the same time, use PTFE tape only on metal thread, tighten everything hand tight plus half a turn, flush the pipe through without the aerator and test again the next morning.

Then in an hour you have done something a plumber charges a call-out fee for. And you now also know where your stopcock is, which will be worth its weight in gold one day.

Want to take on more jobs like this around the house yourself? In Koning van je Woning I show you step by step how to tackle your bathroom, kitchen and walls, with the sequences, sizes and materials the professionals use. Have a look here.

Cheers, Fred Schouten, builder and DIYer through and through

PS: before you start, take a photo of the existing setup under your sink. Which hose goes where, which valve is the hot one, how the trap runs. When you are lying with your head in the cupboard an hour later trying to work it out, that photo on your phone is worth more than every instruction manual put together. Small tip. Big difference.