Grid congestion is congestion on the electricity network: at a given moment, more power is being drawn from or fed into an area than the cables and transformers can carry. The network operator then cannot offer new or larger connections until the network has been reinforced.

Two directions

What a householder notices

For domestic customers the constraint is usually on export. Nominal low-voltage supply in most of Europe is 230 V, with a permitted band under EN 50160 of roughly 207 to 253 V. When many inverters in one area export at once, voltage rises at the far end of the cable. Above the upper limit an inverter shuts itself down — not a fault, but a mandatory protective function that safeguards other appliances. The result is that the system produces nothing at precisely the sunniest moment.