Airtightness is the degree to which a building envelope resists uncontrolled air flow. It is a measurable property: the less air passes through the joints at a given pressure difference, the more airtight the building.

Where airtight construction is about workmanship, airtightness is about the number that comes out of it.

How it is measured and expressed

Measurement is by blower door test (fan pressurisation to BS EN ISO 9972): a fan in a doorway puts the building under positive and negative pressure.

Different countries use different indicators:

Indicator Definition Used in
Air permeability, q50 Air flow per m² of envelope area at 50 Pa, in m³/(h·m²) United Kingdom
n50 Air changes of the internal volume per hour at 50 Pa, in 1/h Germany, Passivhaus
qv;10 Air flow per m² of floor area at 10 Pa, in dm³/(s·m²) Netherlands

Indicative benchmarks: the Passivhaus standard requires n50 of no more than 0.6 air changes per hour. UK Building Regulations set a maximum air permeability for new dwellings, with typical designed values well below that limit; the exact figure depends on the current edition of the approved documents in your jurisdiction, so check the version in force.

Because reference area and test pressure differ, these figures cannot be converted into one another directly.

Why testing pays

> Note: airtight is not the same as vapour-tight. A construction can be airtight and vapour-open at the same time — with many timber frame details that is exactly the intention.