A weep vent — also called a weep hole vent or vermin-proof weep — is a small grille or insert placed in an open perpend (head) joint of a cavity wall. It keeps the opening clear for air and water while closing it to mice, wasps, bees and birds. Its size matches the perpend joint between two brick headers.

Why those openings are there

Open perpends are not sloppy workmanship but a technical requirement. They let the cavity ventilate and they allow any water that gets behind the outer leaf to run out over the cavity tray. They are therefore always placed where the masonry is interrupted or closed off horizontally:

UK guidance (NHBC Standards and PD 6697) puts weep holes over cavity trays and openings at a maximum of 450 mm centres — roughly every second brick — with at least two per tray run or lintel, and the first and last within about one brick of each end. Always follow the designer’s detail as well.