A vapour barrier is a layer in a wall, roof or floor construction that virtually completely prevents the transport of water vapour through diffusion. It is fitted on the warm side of the insulation and has a much higher vapour resistance than a vapour control layer (VCL). In typical north-west European building physics, a true vapour barrier is mainly used in cold and freezer stores, swimming pools, saunas and certain specialised build-ups.

Difference between vapour barrier and VCL

The distinction lies in the Sd value:

In ordinary residential construction a VCL is usually enough. A true vapour barrier becomes necessary only when there is high indoor vapour pressure, such as in:

Materials

A vapour barrier is usually made of:

Installation and detailing

A vapour barrier only performs if it is fully sealed:

  1. Install on the warm side — directly behind the internal lining
  2. Lap the joints — at least 100 mm overlap
  3. Tape the laps — with vapour-tight butyl or acrylic tape
  4. Seal penetrations — grommets or special tape around cables and pipes
  5. Edge connections — finish with tape and sealant

Points to consider

Application in normal housebuilding

Most houses in northern Europe do not use a true vapour barrier; a vapour control layer (Sd 2-5 m) is enough. A real vapour barrier is usually found only in: