What is a pad foundation?

A pad foundation carries a building’s loads at points: on individual heavy blocks of reinforced concrete — the pads — instead of on a continuous strip or a full slab. Ground beams between and over the pads take wall loads to them.

As long as the pad bears directly on a competent stratum, it is a form of shallow foundation. If a pile sits beneath it, the block over the pile or pile group is called a pile cap, and it is then a piled foundation.

When to choose one

The pad foundation is the obvious choice as soon as the load is naturally point-shaped:

With a strip foundation the load is spread over the whole length; with a pad it concentrates on a few square metres. The bearing pressure under the pad is therefore much higher, and that makes the ground conditions decisive.

Sizing and points to watch

  1. Ground investigation first. The pad size follows from the load divided by the allowable bearing pressure. Without a site investigation any dimension is a guess — and with a point load a wrong guess shows up immediately as differential settlement.
  2. Found below frost depth. In north-western Europe the underside of the foundation is normally taken at least 600 to 800 mm below ground level to avoid frost action in the soil beneath.
  3. Differential settlement. This is the weak point of the type. Pads with different loads or on different strata settle differently. Stiff ground beams between the pads spread those differences out.
  4. Reinforcement. A pad must be reinforced to resist punching shear from the column and bending at its underside; a plain concrete block only works for very light structures.
  5. Connection to the column. Base plate, holding-down bolts or starter bars must be cast in at the correct position. Drilling into a green pad afterwards weakens it.

Pad foundation: checks before and during casting

  • Ground investigation done: Pad size follows from load divided by allowable bearing pressure; without it any dimension is a guess.
  • Underside below frost depth: In north-western Europe normally at least 600 to 800 mm below ground level.
  • Stiff ground beams between pads: They spread out differential settlement between pads.
  • Pad reinforced: Resists punching shear from the column and bending at its underside; plain concrete only for very light structures.
  • Column connection cast in: Base plate, holding-down bolts or starter bars at the correct position; do not drill into a green pad afterwards.
Points to watch when sizing and building a pad foundation, as described in this article. Frost depth applies to north-western Europe.