A leak detection system is a system that signals and locates a breach in a waterproofing layer without opening up the construction. On flat roofs this matters because the point where water appears indoors is rarely the point where the leak is: water travels along the vapour control layer or the deck before it drops through.

Two families are commonly grouped under the same name: permanently installed monitoring systems, and one-off measuring methods used to find a leak after the fact.

Permanent monitoring

In a permanent system, sensors or a measuring grid are built into the roof build-up, usually in or beneath the insulation layer. The system measures continuously or at intervals whether moisture is present anywhere in the build-up — for example by determining the electrical resistance or the potential difference between measuring points. With enough measuring points the system indicates not only that moisture is present but where.

The big advantage is time: moisture is reported before it becomes visible indoors, so the amount of wet insulation stays limited. The main limitation is that such a system essentially has to be included when the roof is built or refurbished — retrofitting means opening the roof up.

Electronic leak detection after the fact

For existing roofs there are measuring methods that need no built-in sensors:

Which leak detection method suits which roofUnballasted, dry roof→High-voltage spark testingUnder gravel, paving or a greenroof→Low-voltage vector mappingChecking leaking seams→Vacuum testingFinding saturated insulation zones→Thermography and moisture metering(shows the wet area, not always theexact hole)Wet roof→No high-voltage test: gives falsereadingsBone-dry roof→No low-voltage test: gives nothingat all
Choice of after-the-fact leak detection method by roof condition, as described in this article. Electronic methods require an insulating membrane above a conductive substrate; ask a contractor which method and which guidance they work to.

Requirements and practical points

International guidance for electronic leak detection exists (from ASTM among others), setting out the methods and their preconditions; ask a contractor which method and which guidance they work to.

Related terms

Want to know more about building terms? Take a look at our knowledge base on fredsdiyplans.com.

Leave a Reply

Your email address will not be published. Required fields are marked *