The short answer first: you replace a radiator by switching off the boiler, isolating the radiator and draining it, undoing the union nuts and lifting the old radiator off its brackets. Then you hang the new one level, connect it to the existing pipework with compression fittings, refill the system to roughly 1.5 to 2 bar and bleed everything at least twice. For a like-for-like swap in the same spot, that is two to four hours of work.
That is the short version. The real work sits in two things most step-by-step guides skip: choosing the right radiator (does it fit your pipework, does it give off enough heat?) and getting the system back up to pressure and free of air afterwards.
Below you will find when replacing makes sense, how to pick the right type and output, the full step-by-step, what it costs, and the mistakes you want to avoid. Plus the story you really need to know if you are on a heat pump, or heading that way.
When should you replace a radiator?
A radiator lasts a long time, but not forever. Replace it if you see any of these:
- Rust and leaks. Brown streaks under a fitting or a damp patch on the floor. With a leaking radiator, replacing is almost always smarter than carrying on repairing.
- Cold spots that do not go away. If the bottom stays cold while the top is warm, there is air in it (bleed it). If the top stays cold instead, there is sludge sitting in the bottom. If flushing does not shift it, the radiator is finished.
- Not enough output. The room simply does not get warm enough, even with the radiator fully open. That means it is undersized.
- You are renovating or upgrading the house. New layout, better insulation or a switch to a heat pump. That is exactly the moment to fit the right radiator straight away.
- Purely for looks. Old column radiator out, a neat panel or designer radiator in. Perfectly good reason, but do check the output first (see below).
Replacing a radiator is a job you can do yourself if you are reasonably handy. You are working with water, not with gas or with the electrics inside the boiler. Unsure about draining, or not keen on touching the system pressure? Then a heating engineer for this job is money well spent.
Which type of radiator do you choose?
Most radiators in homes are panel radiators. You recognise them by a type number: 10, 11, 20, 21, 22 or 33. That number tells you exactly what the radiator can do.
- First digit: the number of panels (the hot plates).
- Second digit: the number of convector fins (the folded strips in between that give off extra heat).
So a type 22 has 2 panels and 2 sets of convector fins. A type 33 has 3 and 3. The higher the number, the deeper the radiator and the more heat it gives off at the same height and length.
| Type | Panels + convectors | Character |
|---|---|---|
| 10 | 1 + 0 | Thin and flat, low output |
| 11 | 1 + 1 | Slim, suits small rooms |
| 21 / 22 | 2 + 1 / 2 + 2 | The standard for living rooms and bedrooms |
| 33 | 3 + 3 | Chunky, plenty of output on very little wall |
The difference is big. According to Dutch consumer body Milieu Centraal, a type 11 gives roughly 850 watts, a type 22 around 1,450 watts and a type 33 about 2,200 watts (at comparable dimensions and a classic high boiler flow temperature). So a type 33 pulls far more output out of the same bit of wall than a type 11.
Handy if, say, you want to replace a wide old column radiator with something shorter: pick a deeper type, so you keep the same output over less length.
How much output do you need?
This is where it goes wrong: people buy “the same size again” and end up short of heat, or hang something needlessly heavy. Do the sums.
Rough rule of thumb:
- Measure the room: length x width x height = volume in m³.
- Multiply by a guide figure per m³.
The usual rule of thumb is around 85 watts per m³ for a living room, about 70 watts per m³ for a bedroom and roughly 90 watts per m³ for a bathroom (you want that one warmer). These are rules of thumb, not a standard.
Then correct for your house:
- Poorly insulated: add about 15 per cent.
- Well insulated: take off around 10 per cent.
- Very well insulated (new build, everything double glazed): take off up to a quarter.
- End-terrace or detached house: add a bit.
Example: a living room of 5 x 4 x 2.6 metres is 52 m³. Times 85 watts is roughly 4,400 watts. With good insulation you take off about 10 per cent, which puts you around 4,000 watts. That could be one big radiator, or two smaller ones together.
Want to know it properly (for a heat pump, for instance)? Then have a room-by-room heat loss calculation done. That is more accurate than any rule of thumb.
Will the new radiator fit your pipework?
Before you order anything: measure the connection spacing. Otherwise your lovely new radiator will not line up with the pipes coming out of the floor or wall.
- Centre-to-centre spacing. On a radiator with bottom connections, the standard distance between the two connection points is 50 mm. Most connection kits are made to match.
- Pipe diameter. In most homes the heating pipework is 15 mm.
- Flow and return. Make sure the new radiator has its connections on the same side as your existing pipes, or choose a model with a central bottom connection.
Is the existing pipe spacing different? There are adjustable fittings (S-shaped connectors) that take up a few centimetres of play. So measure twice rather than once, and take the dimensions with you to the shop.
Special case: replacing a radiator for a heat pump
This is the most important tip in this whole article, and it is the one that is missing almost everywhere.
An ordinary gas boiler heats water to 70 or 80 degrees. A heat pump works with low temperature heating: the water is then only 30 to 55 degrees. That is more comfortable and cheaper to run, but it does mean a radiator gives off far less heat, because the temperature difference with the room is smaller.
The result: for the same heat you need a much larger emitting surface. As a guideline, the figure that goes around is roughly three times the size at a flow temperature of about 45 degrees, and more again if you go lower. Milieu Centraal confirms the principle: a lower water temperature calls for more radiator surface.
That leaves you roughly three options:
- Bigger or deeper radiators (a type 33 instead of a 22, for example, or simply physically longer and taller).
- Low temperature radiators, built specifically for low flow temperatures, often with a built-in fan that actively blows the heat out.
- Fan convectors: compact, very little water content, plenty of fins, and they warm up fast.
Moving to a heat pump within a few years? Then size your new radiator generously now. Otherwise you will be replacing it twice.
What tools do you need?
Get this lot ready before you start:
- Allen keys (for the lockshield valve and sometimes the bleed valve)
- Open-ended or ring spanners, or an adjustable spanner
- Spirit level
- Drill with plugs and screws for the brackets
- PTFE tape (or jointing compound) for the threads
- Compression fittings or a complete connection kit
- Hacksaw or pipe cutter (only if you need to alter the pipework)
- Radiator bleed key
- Bucket or shallow tray and a stack of old towels
That last one is not a luxury. The water out of an old radiator is brown, it stinks and it stains. Cover everything properly.
Replacing a radiator: the step-by-step
Step 1: switch off the heating and let it cool
Switch off the boiler (unplug it or use the main switch) and let the water cool down. You do not want to be working with boiling hot heating water.
Step 2: isolate the radiator and drain it
Close the radiator valve and shut the lockshield valve (the return side) as well with an Allen key. On a like-for-like swap you can often isolate and empty just that one radiator, without draining the whole system. Put a tray underneath, open the bleed valve and carefully slacken one union nut so the water can run out.
Changing the model or the position, or do you need to alter the pipework? Then drain the whole system at its lowest point (usually a drain cock on the ground floor, where you can fit a garden hose).
Step 3: old radiator off
Undo the union nuts on both sides completely. There is always more water waiting to come out, so keep those towels to hand. Lift the radiator off its brackets and put it outside or on a dust sheet. A cast iron one weighs a ton, so make that a two-person job.
Step 4: hang the new radiator
Fit the brackets level on the wall. Hang the radiator very slightly out of level: the end with the bleed valve a few millimetres higher than the valve end. The air then gathers at the bleed valve by itself and comes out more easily. Fit the bleed valve and the blanking plug.
Step 5: connect it up
Connect the flow to the (thermostatic) valve and the return to the lockshield valve, using compression fittings and PTFE tape on the threads. Mark or remember which pipe is the flow, so you do not swap flow and return. Tighten the fittings firmly, but do not force them.
Step 6: fill and check for leaks
Open the valves and fill the system through the filling loop to roughly 1.5 to 2 bar (cold). Then go round every single fitting with a dry cloth. If you feel any moisture, nip it up a little further.
Step 7: bleed and adjust the pressure
Run the boiler for a while, turn the thermostat up and bleed the radiator with the bleed key until only water comes out. With a new radiator, bleed at least twice with some time in between. Bleeding drops the pressure, so top it back up into the green zone afterwards. Start bleeding on the ground floor and finish on the top floor.
The right system pressure: what to watch for
Pressure is the thing that makes a lot of DIYers nervous, and it really should not. Remember this:
- Cold: roughly 1.5 to 2 bar is fine. Around 1.8 bar is a good starting point.
- Too low (below 1 bar): the water circulates poorly and your pump can be damaged.
- Too high (heading for 3 bar): it raises the risk of leaks and the pressure relief valve can let go.
- As the system heats up, the pressure may rise by half a bar to a full bar. That is normal.
Does the pressure keep dropping back after a few days? Then there is still air in the system (bleed it again) or there is a small leak somewhere.
Source: manufacturers such as Nefit Bosch and energy suppliers such as Essent quote these same figures.
Fit a thermostatic valve while you are at it
While the radiator is off anyway: consider replacing the manual radiator valve with a thermostatic one.
A manual valve is one you open and close yourself. A thermostatic valve regulates itself: it shuts off the water supply as soon as the room reaches the set temperature. That saves gas, because the radiator stops heating once the room is up to temperature. It is barely any extra work while the radiator is off.
Flush an old system before you hang a new radiator
Old heating systems collect sludge, rust (the black magnetite) and limescale. That makes your heating slower and less efficient, and it can damage the pump and the heat exchanger in your boiler.
Replacing a radiator on an old, dirty system? Then it is smart to have the system power flushed before you hang the new one. Otherwise all that old muck gets pumped straight through your brand new radiator. After flushing, a heating engineer will usually add an inhibitor: a fluid that slows corrosion and sludge forming. It lasts about a year and gets topped up at the annual boiler service.
What does replacing a radiator cost?
Broadly two cost items: the radiator itself and, if you have it done for you, the installation. Work with ranges, because prices vary by type and by company.
| Item | Guide price (2026) |
|---|---|
| Standard panel radiator for a living room | €80 – €150 |
| Designer radiator | €300 – €600+ |
| Cast iron or column radiator | €150 – €400 |
| Connection kit / valve | a few tenners |
| Having it replaced, including fitting (per radiator) | €250 – €600 |
| Moving pipework | often several hundred euros extra |
Do the whole thing yourself and you stay at the price of the radiator plus a few fittings. Have it done and the labour comes on top. A like-for-like swap in the same spot is usually a two to four hour job for a professional.
Common mistakes
- Buying “the same size” without checking the output. Especially after insulating or with a heat pump, you will be well off the mark.
- Not measuring the connection spacing. The radiator does not fit the pipework and you are left standing there empty-handed.
- Swapping flow and return. The radiator will not heat up properly.
- Not bleeding enough. Once is not enough with a new radiator. Do it at least twice and top the pressure back up afterwards.
- Not flushing an old system. You pump old muck through a new radiator.
- Overtightening fittings. Too tight leaks just as readily as too loose, because you damage the seal.
Frequently asked questions
Can I replace a radiator myself?
Yes, a like-for-like swap in the same spot is a perfectly good DIY job if you are reasonably handy. You are working with water and fittings, not with gas. What matters is isolating the radiator properly, getting the connection spacing right, and bleeding it and resetting the pressure neatly afterwards. If pipework needs moving, or you would rather not touch the system pressure, bring in a heating engineer.
Do I have to drain the whole system to replace one radiator?
Usually not. For a replacement in the same spot you can often isolate just that one radiator (valve and lockshield both closed) and drain it. Only if you are moving the radiator or altering the pipework do you drain the whole system at its lowest point.
What radiator output do I need?
Work out the room volume (length x width x height) and multiply by a rule of thumb: around 85 watts per m³ for a living room, about 70 for a bedroom and roughly 90 for a bathroom. Correct for insulation: with good insulation take off around 10 per cent, with poor insulation add some. For a heat pump, or for genuinely precise advice, have a heat loss calculation done.
What is the right system pressure after replacing a radiator?
Roughly 1.5 to 2 bar cold, with around 1.8 bar as a good starting point. Below 1 bar the water circulates poorly, and heading towards 3 bar you get a leak risk. As the system warms up the pressure may rise by half a bar to a full bar. That is normal.
Can I replace my old radiator if I am getting a heat pump?
Often yes, but usually with a bigger one. A heat pump works with much cooler water (30 to 55 degrees instead of 70 to 80), so a radiator gives off less heat. That means you need a considerably larger surface, or special low temperature radiators or fan convectors. If a heat pump is coming soon, size your new radiator generously now.
How long does replacing a radiator take?
A like-for-like swap in the same spot usually takes two to four hours, including draining, hanging, connecting, filling and bleeding. If you have to move pipework or drain the whole system, you will be at it longer.
Are you renovating, with the radiators and pipework all coming out? Then you want it right on the drawing first time round: where the radiators, pipes and connection points go, so your heating engineer knows exactly where everything belongs. At Fred’s DIY Plans we help you with building drawings that have your services properly planned in. It saves you a lot of puzzling afterwards, and you know for certain that the new radiator ends up in the right place, on the right pipes.